The digital permanent makeup machine micro-needle is in the hand, any new machine can be made only a minor adjustment, its fundamental nature, as early as when it leaves the factory has been qualitative, fine-tuning. This is directly related to the gap and the power of the shrapnel. The following links that allow us to adjust: front and rear shrapnel, rear spacing, contact screws, damper rings, coil positions, rubber bands, armatures. The coils, cores, racks, and capacitors are basically fixed. Usually, if the tattoo artist is colored, the totem needs a large machine power and a slow frequency. The traditional sketches of black and white require a small machine power and a fast frequency. You can adjust the appropriate machine according to the above rules. First use the screw to tighten the handle, use a magnifying glass to check whether the tattoo needle is intact. If the needle is good, insert a T-shaped rubber ring at the ring of the needle bar (random delivery), insert the tattoo needle from the upper end of the handle, and then The rubber ring is placed over the cylindrical position of the square iron. Then put the needle tube on, adjust the position of the handle, hold the micro-needle of the digital permanent makeup machine with your left hand, press the cylinder of the square iron with your thumb, press down hard, let the square iron touch the iron core of the coil, adjust the handle with the right hand. Let the tattoo needle stick out of the needle mouth about 1-1.5mm (that is, about half the thickness of a dollar coin). Use a rubber band to tie the needle bar and the body waist at about 8 mm below the bottom of the needle bar. The tightness is moderate to prevent the tattoo needle from coming out during work. Too tight will affect the rotation speed. This will install a machine. Turn on the machine and it will be ready to use.

If the digital permanent makeup machine micro-needle is not activated, we can see if it is caused by the following problems. Is the elastic rod not touching the contact of the oblique spring piece, twisting the screw to make the elastic rod rotate downward to touch the contact, and then adjust to the appropriate position, and tighten the screw to lock the elastic rod. The adjustment button (VOLTAGE) and the V-table pointer are simultaneously at the zero position, the adjustment button is rotated clockwise, and the V-table pointer is also rotating, and the V-table pointer should be stopped at 6-10V. When the elastic rod touches the front edge of the spring piece, it is too tight to touch, and it may not be able to turn the power supply.


Send Inquiry